Solis inverter rs485 fail 3. . The following could be causing the communications to be failing: 1. Specifications User Manual Technical Data S6-EH1P3K-L-PLUS S6-EH1P3. It maximum PV string input current is up to 20A, which can be used for a variety of efficient PV modules, supporting more than 150% DC oversize, High efficiency, Stable and Reliable; Compatible with RS485 / PLC/Wi-Fi/GPRS communication modes, AC 2. If inverter uses the CAN method, connect the CAN (high, low) lines to Terminals 5 and 6. I would prefer to keep this in place, at least during the warranty period. Switch the DC Isolator OFF. Jan 11, 2025 · In the video 1st boot setup and settings have been performed of the solis 6kw plus hybrid Ongrid inverter. Cause The communications between the EPM and the inverters is failing. La tensione RS485 dovrebbe essere di ~1,7Volts in DC. Check the inverter and the meter to make sure they are both powered on. The document has undergone revisions to add more register addresses and functions Apr 29, 2024 · De 4-pins COM poort is een groene aansluiting aan de onderkant van alle Solis omvormers. Oct 16, 2023 · Installed Solis RAI-3K-48ES-5G inverter and bought a Pylontech US5000. Tips:RS485 cable: preferred 0. Jun 15, 2022 · The alarm "MET_Comm-FAIL" is given when the inverter does not detect the external Acrel meter and it is expecting to. In this video, Paul from Status continues his series on inverter troubleshooting by addressing the common issue of a "Meter SLT Fail" alarm. El datalogger comercial S3-Logger está diseñado para plantas fotovoltaicas C&I. 6K-L-PLUS Input DC (PV side . Inverter and meter communication failure -FailSafe is enabled. M: LinkPort0. We’ll only need pins 3 and 4, which correspond with pins A and B on the RS485 HAT respectively. Inputs up to 16A (60K) and 20A (30K) Over 1. We'll not only decipher what these messages mean but also Select the method that matches the inverter communication method in the part marked. Pin 1 = +5 volt CC. pdf (592. L: Erdungsschraube. The COM port of the Solis inverter has 4 pins, conveniently numbered 1-4. RS-485 voltage should read ~1. EPM ha perdido la conexión RS485 con uno o más inversores del sistema. fault There are fault alarm in inverter, need to check inverter status. Jun 20, 2024 · The issue is the work involved taking RS485 RTU signals, converting to TCP and no doubt then back again at the inverters. Jan 12, 2024 · For Example, if you have an inverter with a RS485 connection and you are updating via the green Port, there could be a communication crash and the update will become corrupted. Wenn Sie eine Pylon US5000-Batterie und Solis-Wechselrichter anschließen müssen: HINWEIS: BITTE VERWENDEN SIE DAS VON PYLON MITGELIEFERTE CAN-KABEL . 11, the RS485 terminals for inverter and EPM are already assembled. L'EPM ha perso il collegamento RS485 con uno o più inverter. Page 28 8. 11, connect communication cable between inverter with EPM, and then measure the distance from EPM to inverter. Inverter and external (Acrel) meter are not communicating. Dec 27, 2022 · No experience with Solis kit but an RS485 connection could well be a local network for connection to an energy meter, battery pack or another inverter. Connect with Solis Can't find what you're looking for? Let us help you right now! Submit a Ticket Mar 5, 2025 · Join expert-led events to enhance your knowledge of Solis inverters and solutions. You should check the connection between the RS485 bus and the EPM by doing the following: ① Unplug the RS485 bus connector and use a multimeter to measure the voltage between the A pin and the B pin, which in normal state should read Jun 20, 2024 · The issue is the work involved taking RS485 RTU signals, converting to TCP and no doubt then back again at the inverters. Solis Display Messages. Cumplimiento con UL 1741, IEEE1547. Nov 1, 2022 · Checking the voltage on pins 3 and 4 with a multimeter will ensure RS485 signal between the inverter and the communication device. "RS584 Fail" will also show on the screen between the inverter and the meter. Welcome to Solis Academy At Solis Academy, we are committed to empowering our partners and customers with the knowledge and skills needed to maximize the potential of our inverter technology. 5mm. Pin 1 = +5 volts DC. We are showing tips and tricks on how to isolate your problem. My question is, can two RS485 devices Confiabilidad La seguridad Capacidad S3-Logger. May 17, 2022 · Troubleshooting connection issues with the Solis Inverter. 5 - Battery and Inverter Connection: Procedura di ripristino dell'HMI dell'inverter Solis 4G/5G. The noise will increase, cooling air ducts and the fan will become blocked, resulting in inverter failure. This is the terminal furthest to the right (MTR485A) Land the B wire from the meter in terminal 9 of the communication port inside of the inverter May 14, 2024 · L'EPM ha perso il collegamento RS485 con tutti gli inverter dell'intero sistema. 6. If you ever need to extend it see the pinout below: 6&8 for + 3&7 for - Connect with Solis Aug 23, 2024 · Solis Hybrid - MET_SLT-FAIL. The protocol supports functions like reading input states, acquiring device information, reading operation data, setting registers, and examples. Mar 14, 2025 · It is not recommended to choose an area with heavy ash accumulation, fallen leaves, or overgrown weeds. I found the doc for the standard inverters on the us service site, I think it’s this doc… Solis WiFi Configuration - S3-WIFI-ST/S2-WL-ST Modifié le Mer, 10 Janv. This works but your inverter needs to read RS485 TCP on a LAN. 5 DC/AC ratio for greater power density; Integrated MC4 connections and spring clamp terminals ensure faster install times while also ensuring cables are properly secured Aug 23, 2024 · Solis EPM - Setup (Export Power Manager) In this video, you'll receive a comprehensive walkthrough of the commissioning process for an Energy Power Manager (EPM) and its integration with inverters. Jun 9, 2022 · First, an RS485 communication cable will need to be ran between the meter and the inverter ; Land the A wire from the meter in terminal 10 of the communication port inside of the inverter . Stupidly thought it would be plug and play but I’ve tried everything to get the two to communicate. We'll not only decipher what these messages mean but also offer possible solutions to address them. He explains what this alarm means, why it occurs, and provides a step-by-step guide on how to resolve it by correctly selecting the appropriate meter on the inverter. 3 of the hybrid manual states that only batteries that are on the Battery Compatibility listed can be used with the Solis RHI-1P(5-10)K-HVES-5G-US inverter series. My inverter Solis-RAI-3K-48ES-5G, appears to have much fewer options than the inverter in the post that you've attached. 98. Pylon US2000C/US3000C/US5000 Battery - "Batt_Comm_FAIL" - "No Battery" alarms. Dec 27, 2022 · I have a solis inverter and have not yet had access to their app, installer thinks it is a antenna problem to be rectified this week. The ESP8266 is interfaced with the Solis inverter using RS-485 available on the inverters 'COM' port. Pin 4 = -RS485. Oct 30, 2024 · Amazon, waveshare rs-485/ethernet mqtt gateway. 5 DC/AC ratio for greater power density; Integrated MC4 connections and spring clamp terminals ensure faster install times while also ensuring cables are properly secured Share this article: Share via Email. Please note that this might vary by model and it is your responsibility to check before connecting. This is the terminal furthest to the right (MTR485A) Land the B wire from the meter in terminal 9 of the communication port inside of the inverter Dec 6, 2024 · Solis Display Messages In this article, we will provide a comprehensive explanation for all messages generated by Solis inverters, ranging from operating messages to alarm messages. “RS485 ALLFail” This indicates that the RS485 communication between all inverters and the EPM is faulty. 2. US5000 Frontplatte: Definition des RJ45-Port-Pins . meter interface. These will affect the normal operation of the fan. 7Volts on DC. - Devices: One computer (or other terminal device that can be plugged into a network cable), one router/switch that can provide multiple network ports, and two network cables (choose network cables without a protection Aug 23, 2024 · Solis Hybrid Inverter - CAN Comm Fail. Figure 3: Debris blocks the inverter air ducts and fans, causing inverter failure Apr 18, 2024 · EPM ha perdido la conexión RS485 con todos los inversores del sistema. Vedi tutte 7 Pinout RS485 per connessione meter Pylon US2000C/US3000C/US5000 Batteria - Batt_Comm Aug 29, 2021 · Solis inverter COM port. My main reason for choosing this one EPM har tappat RS485-anslutningen med alla växelriktare i hela systemet. It's a single phase inverter, I don't need three phase backup. The distributor/dealer of Solis Singles Phase Inverter (if available); 3. Alta densidad de seguimiento de potencia 80 MPPT/MW. There are backflow current to grid, customer need to stop inverter. The MAX3485 is 3. Assemble PV input connector to the Inverter. If the inverter uses RS485, connect the RS485 (A+, B-) lines to Terminals 3 and 4. 5A/62. COM port pinout is 1 = +5Vcc, 2 = 0V com, 3 = 'A' 4 = 'B'. If it does say “RS485 Fail” then the inverter and meter are not communicating. A: “RS485 Fail” — this indicates that the RS485 communication between the inverter and the EPM Box in the entire system is faulty. 5 DC/AC ratio for greater power density; Integrated MC4 connections and spring clamp terminals ensure faster install times while also ensuring cables are properly secured We would like to show you a description here but the site won’t allow us. Aiutaci ad aiutarti Gentile Cliente, Per assisterla nel modo più efficiente possibile, avremmo bisogno che ci fornisse informazioni specifiche, che possono variare a seconda della richiesta. EPM har tappat RS485-anslutningen med en eller flera växelriktare. 11 RS485 terminal b. Refer to figure 4. DIP switch for setting communication termination resistor of primary/secondary packs Dec 29, 2023 · Controllando la tensione sui pin 3 e 4 con un multimetro, si verifica il segnale RS485 tra l'inverter e il dispositivo di comunicazione. The use of twisted cables helps reduce electromagnetic noise and improves the reliability of data transmission. Battery Capacity 50 - 2000Ah 1. and check the connections for the RS485 cable between EPM and inverter. Cutting that wire would make it impossible for the inverter to know if there is other generation that needs to be accounted for. The house has three phase power for the heat pump. 3 KB) I am using this to poll modbus data from the wifi logger GitHub - jmccrohan/pysolarmanv5: A python module to interact with Solarman Data Logging Sticks that might help you. This port is a green port located externally on all Solis inverters on the bottom of the inverter. 7% de eficiencia máxima; Soporta RS485, WiFi, GPRS; Corriente por string de hasta 16A; Admite control de exportación de potencia; Diseño compacto, instalación y mantenimiento sencillo; Protección AFCI, reduce activamente el riesgo de incendio Apr 10, 2023 · Note: This modbus map is for the RHI-1P(5-10)K-HVES-5G-US inverter series ONLY and will not work with any other Solis inverter series - there is a different map for the other inverter series. Se l'inverter inizia a generare, lasciare RelayChk-Fail disattivato per 3 ore, dopodiché riattivarlo. I installed a Solis S5 hybrid inverter (S5-EH1P-6K-L) with two Pylontech US5000 and of course solar panels. Physical interface 2. My inverter just has the choice of a 1ph meter or a 3ph meter. We have had over 1 1/2 kw on a sunny day but have come across a problem during the cold spell. Wenn die rs485-Kommunikation nicht funktioniert, wird nichts funktionieren. efficiency 99. K: RS485. pin 2 = -5 volts DC . Specifications for using RS-485 with inverters: Solis is one of the world's largest and most experienced manufacturers of solar inverters supplying products globally for multinational utility companies, commercial & industrial rooftop projects, and residential solar systems. Serial number of Solis Single Phase Inverter; Maximum Charging Power 2. Emailed both Solis and Pylontech support but always get conflicting info. Jun 15, 2022 · ***Connecting the inverter to a battery that is not on the list will void the warranty of the inverter*** Note: Section 5. 4. Überprüfen Sie die Kommunikationskabel zwischen EPM und Wechselrichtern. Se il sistema è trifase, controllare la tensione AC da fase a fase, da fase a neutro e da neutro a terra. Share this article: Share via Email Solis Seminar Episode 37: Key Points of Inverter Selection in BIPV Project May 6, 2024 · RS-485 cable typically consists of two twisted copper conductors, often shielded to protect the signal from external interference. Serial number of Solis Singles Phase Inverter; 2. Das EPM hat die RS485-Verbindung mit einem oder mehreren Wechselrichtern verloren. Ensure you have the INVERTER ADDRESS SET TO 1 (for HMI Update) Solis-(80-110)K-5G-PRO 3-phase series inverter is a new generation of Solis 5G models, designed to provide high quality solutions for C&I PV projects. The specific cable can be replaced with a LAN cable. Please see pages 62-63 of the Solis S6 HV Home Energy Storage Inverter Manual for instructions on how to do this. Page 59 8. Jun 9, 2022 · Once the inverter is properly mounted, run conduit into the inverter's wire box. Figure 4. Ensure the CT is clamped onto the live wire of the power grid, with the arrow pointing in the direction of the grid. The inverters have duplicate addresses 3. You should also check whether the number of inverter settings on the EPM and the inverter's slave address settings are correct. Ideally, the DC should land on the left side/bottom left corner of the inverter whereas the AC should land on the right side/bottom right corner. You should check the May 14, 2024 · L'EPM ha perso il collegamento RS485 con tutti gli inverter dell'intero sistema. You should check the connection between the RS485 bus and the EPM by doing the following: ① Unplug the RS485 bus connector and use a multimeter to measure the voltage between the A pin and the B pin, which in normal state should read about 1. 3V Inversores trifásicos Solis conectados a red Características > relación CC/CA del 150 %. Check that the meter is powered on with 240V and that the RS485 wire is installed correctly. Use proper cable for Jul 30, 2021 · If there is a large deviation from this, it indicates that the inverter's communication terminal could be faulty. Pin 3= +RS485. 1. The meter lights will be lit up if the meter is getting power. Kontrollera kommunikationskablarna mellan EPM och växelriktarna. This allows selected loads to continue to be supplied with backup power in the event of a grid failure. I got a connector with a length of wire attached to it already. Fuchs: LV5200 . This protocol can read operational information and control the inverter in real time. Jul 13, 2021 · Si hay una gran desviación, el pin A y el pin B del terminal RS485 del lado del inversor puede invertirse. I used a MAX3485 to interface the ESP8266 to the RS-485 port. pin 1 = 5 Volt DC + (rood) pin 2 = 5 Volt DC - (zwart) pin 3 = RS485 + (geel) pin 4 = RS485 - (blauw) Controleer of het Solis Three Phase Inverters Models: S5-GC100K-AU S5-GC110K-AU S5-GC125K-HV-AU Efficient Smart Safe Economic • 10 MPPTs, max. We highly value your input and any suggestions you might have to enhance our content. Compruebe todas las conexiones de comunicación entre el EPM y los inversores. ② Si hay problemas intermitentes "fail-safe", puede ser causado por interferencias en el sitio. Amazon UK have one (Ebyte ASIN B0DGQ98XWQ), which won't help you much in Florida Hello everyone! This is in France. This document summarizes the RS485 MODBUS communication protocol for inverters. Solis Three Phase Grid-Tied Inverter Leading Features. The EPM could be looking for more inverters than the amount you have on the system 2. The meter has the following options for communication settings, I believe the baud and mode settings are correct. Make RS485 cable (COMM-INV port) a. Admite conexión tipo «Y» en el lado de CC. Fail safe RS485 AllFail: EPM has lost communication with ALL inverters CT-Failsafe: Current Sensor failed Jan 3, 2024 · Solis S3-WiFi-ST verbinden met uw WiFi netwerk Gewijzigd op Wo, 10 Jan, 2024 om 10:05 AM Soliscloud gebruikershandleiding voor systeemeigenaars en/of organisaties (installateurs) Nov 18, 2024 · Hi Seagal, many thanks for your post. Ein Alarmcode "RS485-all-fail" wird angezeigt, wenn der EPM keine Kommunikation für einen oder mehrere Wechselrichter erkennt. If you've encountered difficulties with the connection between these two components in your solar setup, this guide is designed for you. Integrated switching device for backup power; Great flexibility with 3 MPPT; Parallel connection of up to 10 hybrid inverters via RS485; High input current of 16 A The electrical connection of the inverter must follow the steps listed below: 1. Controllare i cavi di comunicazione tra EPM e inverter. BMS-Schnittstelle: J: KANN. Comunicación de línea de potencia (PLC) (opcional) Sep 16, 2024 · Use the network cable provided in the accessories to connect the power meter's RS485 port to the inverter's RS-485. You should check the connection between the RS485 bus and the EPM by doing the following: ① Unplug the RS485 bus connector and use a multimeter to measure the voltage between the A pin and the B pin, which in normal state should read Dec 27, 2022 · I have a solis inverter and have not yet had access to their app, installer thinks it is a antenna problem to be rectified this week. Función nocturna SVG. protocol between SOLIS grid-tied inverter and PC monitoring software. Jun 15, 2022 · The alarm "MET_Comm-FAIL" is given when the inverter does not detect the external Acrel meter and it is expecting to. 2 Inter-frame interval Inversores trifásicos Solis conectados a red Características. Nov 15, 2023 · If you wish to download this article as a PDF, please scroll to the bottom of the page or click HERE. Nov 29, 2022 · Is your Solis Hybrid Inverter showing an alarm MET SLT FAIL?Check this video to reconfigure for the correct modbus meter. Checking the voltage on pins 1 and 2 with a multimeter will ensure power is provided to the communication device (ex: wifi datalogger. If your expecting to see a value for grid export then have you got or going to have an export meter? Jun 9, 2022 · First, an RS485 communication cable will need to be ran between the meter and the inverter ; Land the A wire from the meter in terminal 10 of the communication port inside of the inverter . Aug 19, 2024 · The inverter should be updated locally using the SolisCloud Bluetooth tool during commissioning. Lift up the inverter (be careful to avoid body strain), and align the back bracket on the inverter with the convex section of the mounting Contribute to briandorey/Solis-Inverter-RS485-to-WiFi-Bridge-via-ESP32 development by creating an account on GitHub. Issue: Solis Hybrid Inverters display a "Batt_Comm_FAIL" previously "CAN_Comm_FAIL" or "No Battery" alarm when connected to US2000C or US3000C/ US5000 Pylon batteries. , 2024 à 1:50 H Comment accéder à l'écran du message d'alarme? - Protocol and Specification: Solis inverter MODBUS RS485 communication protocol, inverter manual, S2-WL-ST data logger manual. Hybrid meter pinouts The hybrid meter cables come standard in the box. This indicates that the RS485 communication between the inverter and the EPM Box in the entire system is faulty. Nov 18, 2021 · Solis RHI-5K-48ES-5G Inverter (supports on grid and off grid) (RS485/CANBUS) Fronus 48V 85Ah Battery (with RS232 as INVCOM and RS485 as BATCOM ) My plan is to buy a Pylontech U-2000C (supports RS485 and CANBUS), also compatible with my inverter, and connect the Fronus battery in parallel (also connect the BATCOM to the Pylontech ). You need to test the voltage between RS485A and RS485B to confirm it is working. Der Export Power Manager benötigt eine rs485-Kommunikation, um Daten zu erhalten und die Wechselrichter zu steuern. The voltage reading should be 5V on DC. pin 2 = -5 volt CC . MET_Comm-FAIL. EPM hat die RS485-Verbindung mit allen Wechselrichtern im gesamten System verloren. Oct 9, 2022 · 2. Aug 15, 2024 · This setting is to prevent the inverter from exporting power if meter communication fails. INV. Es capaz de recopilar datos de 4 puertos RS485 simultáneamente y traer datos de inversores Solis, medidores Solis, sensores de irradiación de terceros, sensores de viento de terceros y estaciones meteorológicas de terceros. Installation date. Jul 30, 2021 · If there is a large deviation from this, it indicates that the inverter's communication terminal could be faulty. The alarm "MET_Comm-FAIL" is given w Jun 9, 2022 · RS-485 Wiring with Circular Connector Created by Victor Herrera, Modified on Thu, Jun 9, 2022 at 10:26 AM by Victor Herrera Circular Connector: Pin 1 = Red = Positive 5 Volts, Pin 2 = Ground, Pin 3 = Yellow = RS485+, Pin 4 = Blue or White = RS485- Jul 9, 2021 · If this message does not appear it means that the inverter’s “failsafe” option is switched off. Oct 15, 2024 · Se il problema persiste e il guasto non viene riconosciuto, disattivare la funzione RelayChk-Fail nel Menu Special Seetings. Switch the Grid Supply Main Switch (AC) OFF. 0% • > 150% DC/AC ratio • High power tracking density 100MPPT/MW • String current up to 16A, perfectly match large current bifacial modules • Night SVG function YELLOW = +RS 485 = Pin 3 ; BLUE = -RS 485 = Pin 4; Thank you for taking the time to explore the local firmware procedure for Solis inverters in our article. We tried several RS485 Pi hats, but all had the same issue. With the Solis inverter connected to the Raspberry Pi, we were initially unable to communicate with the inverter, and the Python scripts returned connection errors. Überprüfen Sie alle Kommunikationsverbindungen zwischen EPM und Wechselrichtern. Controllare tutti i collegamenti di comunicazione tra EPM e inverter. Make sure the RS485 between the inverter and meter is installed May 16, 2022 · RS485_MODBUS Communication Protocol_Solis Inverters (1). N: POWER-2 . More difficult if you want to also use the wifi dongle on the Solis; the inverter is the slave on rs-485 so you need a dual-master 485 hub. Communication CAN/RS485 4. Jul 7, 2021 · If there is a large deviation from this, it indicates that the inverter's communication terminal could be faulty. The Solis Hybrid Inverter has an integrated switching device for backup power. 5 DC/AC ratio for greater power density; Integrated MC4 connections and spring clamp terminals ensure faster install times while also ensuring cables are properly secured Mar 10, 2021 · I have a RHI 5k 48es inverter and wish to control the battery charging times by RS485/Modbus However, the installer fitted a Wifi Datalogger to upload the stats to the Ginlong website. Fail safe alarm-01 Description The EPM is reporting an alarm of fail-safe-01. You should check the connection between each inverter and the RS485 bus; Use a multi-meter to measure the voltage between the A pin and B pin of each inverter's RS485 communication port which under normal operation should read about Aug 22, 2024 · Solis Hybrid Inverter - Meter Troubleshooting In this video, we will focus on a critical element of solar power systems: addressing communication issues between your inverter and meter. The description of the problem together with necessary information, pictures, attachment. Modified on Fri, 23 Aug, 2024 at 1:01 PM Jun 20, 2024 · The issue is the work involved taking RS485 RTU signals, converting to TCP and no doubt then back again at the inverters. The distributor/dealer of Solis Single Phase Inverter (if available); Maximum Charge/discharge current 62. CAN / RS485 ist die Oct 24, 2022 · Stand alone RAI would have this CT at the wire connected to the grid ( your circuit breaker board wire that connects to the incoming AC line ) OR measuring an AC coupled second gridtie inverter AC output . In this article, we will provide a comprehensive explanation for all messages generated by Solis inverters, ranging from operating messages to alarm messages. 0% de eficiencia máxima. Solis does not recommend installing multiple units of this series in parallel. This needs to be done at both points (device port and cable plug) on each device. 5A 3. Troubleshoot communication between the inverter and meter. 10 MPPT, 99. Your understanding and feedback are essential to us. Sep 29, 2023 · An alarm code "RS485-all-fail" will appear if the EPM doesn't detect communications for one or more of the inverters. RS485 Fail . The wire terminals are spring clamp, so you will need a small common (flat) screwdriver to open them and land the wires. 6V. Instalación de cable RS-485 con conector circular Created by Victor Herrera, Modified on Wed, Jun 15, 2022 at 10:55 AM by Victor Herrera Conector circular: Pin 1 = Rojo = Positivo 5 Voltios, Pin 2 = Tierra, Pin 3 = Amarillo = RS485+, Pin 4 = Azul o Blanco = RS485. When the MET_Comm-Fail alarm occurs, the inverter is not communicating successfully with the meter. be/cFRQJFbnu3wLink:https://youtu Jan 19, 2023 · This video is to help guide installers on troubleshooting their meter. Si este es el caso, se recomienda que actualice a un cable RS485 blindado de mayor calidad. It describes the physical interface, data frame format, and details of the protocol. See the article FailSafe on how to disable this setting if you do not want it enabled. Jul 8, 2021 · This indicates that the RS485 communication between all inverters and the EPM is faulty. MET_Comm-Fail alarm. Jun 15, 2022 · Verify on the main inverter screen that it says “RS485 OK” in the top left corner and not “RS485 Fail”. Kontrollera alla kommunikationsanslutningar mellan EPM och växelriktarna. Specifications 8. I do take an RS485 RTU feed, send the data to MQTT then feed this to a RS485 TCP server for multiple RS485 TCP Clients to read. Q 5: “RS485 Fail” or “RS485 AllFail” alarm is displayed on the EPM box. Paul provides a detailed explanation of how the EPM measures grid power and communicates with inverters using RS-485 Modbus. Link:https://youtu. 1 Adopts RS485 Receiver-Transmitter, Client-Server Model----Baud rate:9600bps ----Parity checking:None ---- Data:8 ---- Stop:1 2. Has anyone got this setup and could you share your cable configuration please.
gjuxf zzsb fjiqfin abwena pflnev yguwx nschzreq snqbtn ntupy ttkos sqdvqn qqrmiydl ezdra tgxvyb yjtt